|
|
Development and Characterization of Pure Matrix Reference Materials for Detection of Transgenic Soybean (Glycine max) MON89788 |
LI Jun1, LI Xia-Ying2, LI Liang3, SONG Gui-Wen2, SHEN Ping2, ZHANG Li1, ZHAI Shan-Shan1, LIU Fang-Fang3, WU Gang1, ZHANG Xiu-Jie2,*, WU Yu-Hua1,* |
1 Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs / Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China; 2 Development Center of Science and Technology, Ministry of Agriculture and Rural Affairs, Beijing 100025, China; 3 Biotechnology Research Institute, Chinese Academy of Agricultural Sciences, Beijing 100081, China |
|
|
Abstract The reference materials (RMs) for genetically modified organisms (GMOs) detection are essential for ensuring the accuracy, reliability and traceability of test results. Among different types of RMs, the pure powder RMs has the characteristics of easy-preparation and reliable property value, therefore, to become the most commonly used RMs for GMO quantification. In this study, the homozygous seeds of transgenic soybean (Glycine max) MON89788 were used as raw materials to develop pure matrix RMs through the steps of raw material identification, grinding, particle size measurement, water content measurement and initial homogeneity test. Particals less than 200 μm in this batch of RMs accounted for more than 80% of total powders, and the water content was measured to be (4.53±0.03)%, less than the acceptable level of 10%. A total of 400 bottles of RMs were developed by filling 1 g powder in bottles. 15 bottles were randomly selected from the whole batch of RMs to evaluate the homogeneity by MON89788 and Lectin qRT-PCR methods, the F-test results showed that the RMs powder was well-homogenized among and within bottles. The minimum sampling amount was determined to be as low as 100 mg according to the standard of DNA extraction together with the homogeneity test results. For short-term stability study, the RMs were evaluated by analyzing 3 bottles stored at 4, 25, 37 and 60 ℃ for 1, 2 and 4 weeks. For long-term stability, the RMs were evaluated by analyzing 3 bottles stored at 4 ℃ and -20 ℃ for 1, 2, 4 and 6 months. The property value of RMs did not show obvious changes with the extension of transportation and storage time. A t test results indicated that the slopes of regression curves (β1) were not significantly different from zero under the transportation and storage conditions at the 95% confidence level. The stability test indicated that the RMs could be transported at room temperature for one month and the long-term stability was up to 6 months. The property value of this batch of RMs was defined as the copy number ratio of transgenic DNA to total DNA (copy/copy), which was collaboratively characterized by 9 laboratories using MON89788/Lectin duplex digital PCR. Statistical analysis of the characterization data revealed no outlier and a nominal distribution of the data. The calculated average of all independent measurement results was assigned as the certified value. The certified value of DNA copy number ratio was calculated to be 1.00. The uncertainty of the RMs consisted of uncertainty components from characterization, homogeneity, and stabiltiy during short-term and long-term storage. The expanded uncertainty was estmiated to be 0.07 by combining the 3 components with a coverage factor k (k=2 at 95% confidence level). The property value was certified to be 1.00 with an extended uncertainty of 0.07. This batch of RMs can be used for the qualitative and quantitative detection of GM soybean MON89788, as well as the evaluation of MON89788-specific methods and laboratory quality control.
|
Received: 15 November 2019
|
|
Corresponding Authors:
*, zhxj7410@sina.com; wuyuhua@oilcrops.cn
|
|
|
|
[1] 金芜军, 沈平, 张秀杰, 等. 2010. 农业部1485号公告-4-2010, 转基因植物及其产品成分检测DNA提取和纯化[S]. 北京:中国农业出版社. (Jin W J, Shen P, Zhang X J, et al. 2010. Announcement No. 1485 of the Ministry of Agriculture-4-2010, Detection of genetically modified plants and derived products-DNA extraction and purification[S]. Beijing: China Agricultural Press) [2] 阚莹, 李红梅, 孟凡敏, 等. 2012. JJF 1343-2012, 标准物质定值的通用原则及统计学原理[S]. 北京: 中国标准出版社. pp. 1-66. (Han Y, Li H M, Meng F M, et al.2012. JJF 1343-2012, General and statistical principles for characterization of reference materials[S]. Beijing: Standard Press of China) [3] 李允静, 宋贵文, 沈平, 等. 2013. 转基因产品检测标准物质“量值”表达方式及其技术实现途径[J]. 中国农业科学, 46(4):800-809. (Li Y J, Song G W, Shen P, et al.2013. The "value" expression pattern and technical procedure for genetically modified organism detection reference materials[J]. Scientia Agricultura Sinica. 46(4):800-809.) [4] 于亚东, 卢晓华, 倪晓丽, 等. 2016. JJF 1005-2016, 标准物质通用术语和定义[S]. 北京: 中国标准出版社. (Yu Y D, Lu X H, Ni X L, et al. 2016. JJF 1005-2016, General Terms and Definitions Used in Connection with Reference Materials[S]. Standard Press of China, Beijing, China) [5] 余逵, 刘清贤, 陈保华. 1994. JJF 1006-1994, 一级标准物质技术规范[S]. 北京: 中国标准出版社. (Yu K, Liu Q X, Chen B H. 1994. JJF 1006-1994, Technical Norm of Primary Reference Material[S]. Beijing: Standard Press of China) [6] 张丽, 宋贵文, 沈平, 等. 2016. 转基因大豆MON89788基体标准物质的研制[J]. 农业生物技术学报, 24(02):143-152. (Zhang L, Song G W, Shen P, et al.2016. Development of genetically modified soybean (Glycine max) MON89788 matrix reference material[J]. Journal of Agricultural Biotechnology. 24(2): 295~304.) [7] 周云龙, 卢长明, 刘信, 等. 2012. 农业部1782号公告-8-2012, 转基因植物及其产品成分检测基体标准物质制备技术规范, 农业部1782号公告-8-2012. 2012[S]. 北京: 中国农业出版社. (Zhou Y L, Lu C M, Liu X, et al. 2012. Announcement No.1782 of the Ministry of Agriculture-8-2012, Detection of genetically modified plants and derived products-Technical specification for manufacture of matrix reference material[S]. Beijing: China Agricultural Press) [8] 周云龙, 吴刚, 宋贵文. 2014. 转基因生物标准物质研制与应用[M]. 北京: 中国质检出版社. pp. 39-61. (Zhou Y L, Wu G, Song G W.2014. Development and Application of Reference Materials for Genetically Modified Organisms[M]. China Quality Inspection Press, Beijing, China, pp. 39-61.) [9] AOCS.2017a. Certified reference material, certificate of analysis, AOCS 0311-A, MON87708 soybean[R]. https://www.aocs.org/crm#n0311a-mon87708-powder-10-g [10] AOCS.2017b. Certified reference material, certificate of analysis, AOCS 0406-D, MON88017 maize[R]. https://www.aocs.org/crm#n0406d-mon88017-powder-10-g [11] Charles D C, Bogni A, Pinski G, et al.2013. qt-eve-gm-006, Event-specific method for the quantification of soybean line MON 89788 using real-time pcr v 1.01 - validation report and validated method[R]. https://op.europa.eu/en/publication-detail/-/publication/ee69e5a6-5fd8-42f3-8e1d-5f8b409aa0e3/language-en. [12] Dobnik D, Demšar T, Huber I, et al.2018. Inter-laboratory analysis of selected genetically modified plant reference materials with digital PCR[J]. Analytical and Bioanalytical Chemistry, 410(1): 211-221. [13] European Commission.2013. EUR 25997 EN - 2013, Certification report, the certification of different mass fractions of DAS-44406-6 in soya seed powder: ERM®-BF436a, ERM®-BF436b, ERM®-BF436c, ERM®-BF436d and ERM®-BF436e[R]. Luxembourg: Publications Office of the European Union. [14] European Commission.2014. EUR 26869 EN-2014, Certification report, the certification of different mass fractions of DAS-81419-2 in soya seed powder, certified reference materials ERM®-BF437a, ERM®-BF437b, ERM®-BF437c, ERM®-BF437d and ERM®-BF437e[R]. Luxembourg: Publications Office of the European Union. [15] European Commission.2004. EUR Report 20988, Certification report, the certification of reference materials of dry-mixed maize powder with different mass fractions of BT-176 maize, certified reference materials ERM-BF411a, -BF411b,-BF411c, -BF411d, -BF411e, -BF411f[R]. Luxembourg: Publications Office of the European Union. [16] European Commission.2007. Report EUR 22698 EN, Certification report, the certification of reference materials of maize seed powder with different mass fractions of the maize event 3272, certified reference materials ERM®-BF420 (ERM®-BF420a, ERM®-BF420b, ERM®-BF420c)[R]. Luxembourg: Publications Office of the European Union. [17] European Union.2012. EUR 25248 EN - 2012, Certification report, the certification of the copy number concentration of solutions of plasmid DNA containing a BCR-ABL b3a2 transcript fragment, certified reference materials: ERM®-AD623a, ERM®-AD623b, ERM®-AD623c, ERM®-AD623d, ERM®-AD623e, ERM®-AD623f[R]. Luxembourg: Publications Office of the European Union. [18] Haynes R J, Kline M C, Toman B, et al.2013. Standard reference material 2366 for measurement of human cytomegalovirus DNA[J]. Journal of Molecular Diagnostics, 15(2): 177-185. [19] Jiang Y, Yang H, Quan S, et al.2015. Development of certified matrix-based reference material of genetically modified rice event TT51-1 for real-time PCR quantification[J]. Analytical and Bioanalytical Chememistry. 407(22):6731-6739. [20] Kline M C, Romsos E L, Duewer D L.2016. Evaluating digital PCR for the quantification of human genomic DNA: Accessible amplifiable targets[J]. Analytical Chemistry, 88(4): 2132-2139. [21] Košir A B, Divieto C, Pavšič J, et al.2017. Droplet volume variability as a critical factor for accuracy of absolute quantification using droplet digital PCR[J]. Analytical and Bioanalytical Chemistry, 409(28): 6689-6697. [22] Mazzara M, Charles D C, Grazioli E, et al.2007b. QT-EVE-GM-004, Event-specific method for the quantification of soybean line A2704-12 using real-time PCR- validation report and protocol - soybean seeds sampling and DNA extraction[R]. https://op.europa.eu/en/publication-detail/-/publication/6b7608cb-c668-4bdb-86c3-f8c9917ab89d/language-en. [23] Mazzara M, Munaro B, Larcher S, et al.2007a. qt-eve-gm-005, qt-eve-gm-008, Event-specific method for the quantification of soybean line 40-3-2 using real-time PCR - validation report and protocol - report on the validation of a DNA extraction method for soybean seeds[R]. https://gmo-crl.jrc.ec.europa.eu/gmomethods/docs/QT-EVE-GM-005.pdf [24] Mazzara M, Munaro B, Grazioli E, et al.2013a. qt-eve-gm-009, Event-specific method for the quantification of soybean event DP-356043-5 using real-time PCR v.1.01 - validation report and validated method[R]. https://op.europa.eu/en/publication-detail/-/publication/457393f2-49be-448e-b65d-c174582d42a6/language-en. [25] Mazzara M, Munaro B, Grazioli E, et al.2013b. qt-eve-gm-008, Event-specific method for the quantification of soybean event DP-305423-1 using real-time PCR v. 1.01 - validation report and validated method[R]. https://op.europa.eu/en/publication-detail/-/publication/4c7d4d59-ef84-4429-b8e9-05d17b760ea3/language-en. [26] Wu Y, Li J, Li X, et al.2019. Development and strategy of reference materials for the DNA-based detection of genetically modified organisms[J]. Analytical and Bioanalytical Chemistry. 411(9): 1729-1744. [27] Yang Y, Li L, Yang H, et al.2018. Development of certified matrix-based reference material as a calibrator for genetically modified Rice G6H1 analysis[J]. Journal of Agriculture and Food Chemistry. 66(14): 3708-3715. [28] Yoo H B, Park S R, Dong L, et al.2016. International comparison of enumeration-based quantification of DNA copy-concentration using flow cytometric counting and digital polymerase chain reaction[J]. Analytical Chemistry, 88(24): 12169-12176. |
|
|
|